Live Values And Status Colors
Turn raw readings into labels people can understand at a glance.
Choose a useful reading
A live value points to a system metric or a check result. CPU, memory and disk apply to compute systems. A switch may be better represented by link status and temperature; a UPS by battery runtime and input power.
Name it for the reader
Use a name that includes the system and meaning: “APP-01 Queue Depth” or “UPS-01 Runtime”. Add the unit where it matters. Avoid a label like value1 that forces someone to reopen the configuration during an incident.
Put it on the grid
Create a text object, choose its live value and set its display text. For a shape, add color conditions using the same reading. Test the boundaries: below a threshold, equal to it and above it.
Handle missing data
A stale reading is not a zero. Keep an Unknown appearance that is visibly different from healthy and failed. Check freshness before interpreting a chart or acting on a value.
Use durations carefully
Uptime and downtime refer to the continuous observed state. Availability excludes intervals with unknown health. Set a rule around a sustained problem when a single failed sample would cause unnecessary restarts.